C-NET (98) -01, C-NET (98) -02, C-NET (98) -11, C-NET (98) -12 (CONTEC) C bus NIC (LAN board.C-NET (98) -01 is a 10BASE-2 / 5 connector, C-NET (98) -02 Is 10BASE-5 connector.C-NET (98) -11 is a 10BASE-2 / 5 / T connector, C-NET (98) -12 Equipped with 10BASE-5 / T connector. In the C-NET (98) -01 and C-NET (98) -12 other than one 2 jumper switch on the board There is one 8-deep dip switch, and there are two 8-deep dip switches for C-NET (98) -11. There is no dip switch in C-NET (98) -02. power consumption  10BASE-5: +5 V = 250 mA  10BASE-2: +5 V = 450 mA  10BASE-T: +5 V = 300 mA Operating temperature range: 0 to 50 °, operating humidity range: 20 to 80% (no condensation) ・ 2 jumper switches: I / O port address setting  Short ■ 0AAEDh, 0AAEFh (factory setting)  Open ■ 55EDh, 55EFh ・ 8 stations dip switch: Selection of LAN connector to use (1) SW-2 (C-NET (98) -01, C-NET (98) -12)  All ON 10BASE-5  All OFF 10BASE-2 (default setting) (2) SW-2, SW-T (C-NET (98) -11)  Below, the order of SW-2 SW-T LAN connector  All OFF ■ All OFF ■ 10-BASE-5  All ON ■ All OFF 10-BASE-2 (Factory setting)  All OFF ■ All ON ■ 10-BASE-T (3) SW-T (C-NET (98) -12)  All OFF 10BASE-5  All ON 10BASE-T (default setting) I / O port address  Software setting: n3D0h to n3DFh, n7D0h to n7DFh 32 bytes occupied (n = A to F)  Set by jumper switch: 0AAEDh, 0AAEFh or 55EDh, 55EFh Interrupt level  Select one from INT 0, 1, 2, 3, 4, 5, 6 (set by software)