EIF-98BW (ELECOM) C bus bus master SCSI-2 board.Two 8-deep dip switches and 4-djunct jumpers There is one switch and three jumper switches each. The old web page of ELECOM does not have the information of whether it corresponds to HDD more than 1GB. It is not compatible with Windows 95. ・ 8-station dip switch SW1: SCSI-ID of board, interrupt level, setting of DMA channel 1-2-3: Board SCSI-ID setting OFF-OFF-OFF: ID = 0 ON-OFF-OFF: ID = 1 OFF-ON-OFF: ID = 2 ON-ON-OFF: ID = 3 OFF-OFF-ON: ID = 4 ON-OFF-ON: ID = 5 OFF-ON-ON: ID = 6 ON-ON-ON: ID = 7 (factory setting) 4-5-6: Setting interrupt level OFF-OFF-OFF: INT 0 (factory setting) ON-OFF-OFF: INT 1 OFF-ON-OFF: INT 2 ON-ON-OFF: INT 3 OFF-OFF-ON: INT 5 ON-OFF-ON: INT 6 7-8: DMA channel OFF-OFF: DMA 0 OFF-ON: DMA 2 (available only for PC-9801E / F / U / UF / XA) ON-ON: DMA 3 (factory setting) ・ 8 stations dip switch SW2: ROM address, main unit model, setting of valid / invalid of SCSI_BIOS 1-2-3: Normal mode ROM address setting OFF-OFF-OFF: D0000h to D0FFFh ON-OFF-OFF: D2000h to D2FFFh OFF-ON-OFF: D4000h to D4FFFh ON-ON-OFF: D6000h to D6FFFh OFF-OFF-ON: D 8000 h to D 8 FFF h ON-OFF-ON: DA000h to DAFFFh OFF-ON-ON: DC000h to DCFFFh (factory setting) ON-ON-ON: DE000 to DEFFFh ※ Due to the ROM address, simultaneous use of this board, EMS and sound functions is not possible.  Also, when using with PC-9801 E / F / M, set D4000h to D4FFFh. 4-5: Setting ROM address in high resolution mode OFF-OFF: XE8000h to XE8FFFh ON-OFF: XEA000h to XEAFFFh OFF-ON: XEC000h to XECFFFh (factory setting) ON-ON: XEE000h to XEEFFFh * "X" stands for "0H" or "FH". 6-7: Setting of machine model ON-OFF: CPU is the model of 8086 or V30 ON-ON: Model with only 286 CPUs in normal mode only (default setting) OFF-OFF: PC-98XA (high res dedicated model) OFF-ON: Model with both normal mode and high resolution mode, high resolution board Installed model 8: Enable / Disable of SCSI_BIOS ON: SCSI_BIOS enabled (factory setting) OFF: SCSI_BIOS disabled ・ 4 series jumper switch JB1: Setting of hold request channel HRQ1, HLA1 = short, HRQ2, HLA2 = open: HRQ / HLA channel 1 HRQ1, HLA1 = open, HRQ2, HLA2 = short: HRQ / HLA channel 2 (factory setting) · Triple jumper switch JB3: Transfer method, I / O page address setting TM0D: Transfer method setting Open: Automatically switch DMA / bus master transfer depending on CPU type (factory setting) Short: Forced DMA transfer   ※ It is used in advanced mode with Epson PC (when used in normal mode    DMA transfer).When using OS / 2, bus master mode is canceled automatically. IOA0-IOA1: I / O page address setting Short-short: CC0H Open-Short: CD0H Short-open: CE0H Open-Open: CF0H